Managing System Files Installing Software Licenses
OmniSwitch 6250/6450 Switch Management Guide May 2012 page 1-37
Licensed Features
License Features Installation Notes
Metro Ethernet-service
OAM (802.1ag, Y-1731,
802.3ah)
CPE test head
G.8032
IPMC VLAN
Dying Gasp
SAA
MVR
Mac Forced Forwarding
PPPoE
Switch/Stack must rebooted after install-
ing licenses.
Allows SMB models to run Metro fea-
tures.
Metro licenses are installed on the units
in a stack only if the keys for all the units
are available; all units must have a metro
license.
If a unit is inserted in the stack without
metro license and primary unit has a
metro license, new added unit will be put
into Pass Thru. Unit in Pass thru can be
recovered by installing the metro license.
If the unit is inserted in the stack with
metro license and primary unit does not
have metro license, newly added unit will
be put into Pass Thru.
Unit in Pass thru can be recovered by
removing the Metro license.
If unit is inserted in the stack with metro
license and primary unit has metro
license, newly added unit will not be put
into Pass thru.
When removing license from primary
element it will be removed for all stack
elements.
GIG Enables gigabit interfaces on
“lite” models.
No reboot required.
Copper ports will be upgraded to provide
gigabit capacity.
Individual units in a stack can be
upgraded.