Alcatel OmniPCX Enterprise R7.1 Installationshandbuch

Stöbern Sie online oder laden Sie Installationshandbuch nach Server Alcatel OmniPCX Enterprise R7.1 herunter. Alcatel OmniPCX Enterprise R7.1 Installation manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 192
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen

Inhaltsverzeichnis

Seite 1 - Installation Manual

Compact Edition, Advanced Edition, Premium EditionInstallation ManualRelease 7.0 - April 2008

Seite 2

Protective earthingThis equipment must imperatively be connected to a permanent earth protectioninstalled according to current legislation.Installatio

Seite 3 -  

Figure 4.51: Alcatel-Lucent 4019 Digital Phone connectors4.6.1.1.2 Commissioning the setThis section describes how to:- Connect the set- Program keysP

Seite 4 - Chapter 4

In fact, only the direct call key can be programmed (with a telephone number), which bydefault is the sixth programmable key. However, the Personal/Di

Seite 5 - Chapter 6

- Connect optional equipment- Program keysPrerequisitesNone.Connecting the setsThis section describes how to connect a set to the telephone system.Pre

Seite 6 - Chapter 8

42 additional keys.- Add-On Modules of types AOM10 and AOM40 can be used on the same set, but a SmartDisplay Module cannot be used in conjunction with

Seite 7

- F1/F2 keys- Add-On Module keys (if any)- virtual add-on keysTwo methods are presented.Programming a keyTo program a key:1. From the MENU tab, select

Seite 8

4.7.1 Hardware description4.7.1.1 OverviewThe V24/CTI Interface Module allows a Data Terminal Equipment (DTE) to be connected tothe OmniPCX Office, vi

Seite 9 -  

- CAN/CSA-C22.2 No 950-95: Canada4.7.1.2.2 ECM- EN55022: Limits and methods of measurement of radio interference characteristics ofinformation technol

Seite 10 - %## $##

___change-end___4.7.2.2 JumpersThe jumper in a gray background is factory installed.___change-begin______change-end___To configure the V24/CTI Interfa

Seite 11

4.7.3 External connections4.7.3.1 V24/CTI Interface Module ConnectionThe V24/CTI Interface Module is connected as follows:___change-begin______change-

Seite 12

___change-end___Figure 4.57: Rear Panel1. RJ11 connector for UA line to PCX2. V24 SUBD9 connector3. CTI SUBD9 connector___change-begin______change-end

Seite 13

The EC labeling indicates that this product conforms to the EC directives currently in force, inparticular:- 89/336/EEC (Electromagnetic compatibility

Seite 14

3 RX Data reception45 GND Protective ground67 RTS Transmission request8 CTS Ready for transmission94.8 Intelligent Base Stations4.8.1 Detailed descrip

Seite 15 -    

Both cables should have the same length. The first interface of the system’s UAI16 boardshould not be used since the operator station uses those point

Seite 16 - 2.2.1.3 Rack 3 or L or LARGE

As a result of the environment and the infrastructure, certain recommendations must be takeninto account for locating Alcatel-Lucent 4070 IO/EO:Recomm

Seite 17

There is no hardware configuration for IBS other than selecting between an external powersupply for each IBS and remote power by system.To configure t

Seite 18

There are 3 possibilities of configuration:- Short line (0-400 meters)- Medium line (400-800 meters)- Long line (800-1200 meters)Restart the IBS after

Seite 19 - 2.3 Installation

___change-end___Figure 4.61: DECT/PWT FrequenciesNote 2:Due to hardware, there is a limit in the number of channels that you can configure.You can con

Seite 20 - 2.4 Equipment

bands in the different countries, 4 types of initialization of frequency plans are available:Europe, Latin America, The United-States and China.table

Seite 21

1 1926.720 1927.5842 1924.992 1924.9923 1923.264 1923.2644 1921.536 1921.5365 1919.808 1919.8086 1918.060 1918.0607 1916.352 1916.3528 1914.624 1914.6

Seite 22

0000 0011 1111 11004.8.2 Safety rules4.8.2.1 ENVIRONMENTAL PROTECTIONFor an exterior installation, it is necessary to take precautions against lightni

Seite 23

External antennaeAccording to the ETSI EN 301 406 standard, DECT antenna gain is limited to 12 dB +/-3dB. Inthe case of external directional antennae,

Seite 24

Figure 1.3: First Generation cabinetChapter1%## $##1-4        

Seite 25 - 2.4.1.4 SLI-X Boards

Square zone Rectangular zoneExample 1: square building Example 2: rectangular building1stfloor 1stfloor2ndfloor 2ndfloorIt is possible to alter the nu

Seite 26 - 2.4.1.6 MIX x/y/z

The solution proposed alternates two stations per floor with overlapping locations from onefloor to another. The zones shown by unbroken circles corre

Seite 27 - 2.4.1.9 PRA Boards

(release 6 and later).Note 2:For more details, refer to the documentation of the operating system used on the client workstation.The following service

Seite 28 - 2.4.1.11 LAN-X Boards

4.9.1.1.2 Ethernet network access boardDynamic IP Address (DHCP)- Reserve a range of addresses for PCs in the system: WBM : Network -> DHCP tab .-

Seite 29 - 2.4.1.12 LANX-2 Boards

Static IP AddressGive an IP address to the Ethernet network card; this address must belong to the samesubnet as the Alcatel-Lucent OmniPCX Office Comm

Seite 30 - 2.4.1.14 ATA Board

Configure the Internet Browser without proxy. In this case, the network parameters of the PCmust be set as shown in the "NETWORK SERVICES" s

Seite 31 - ___change-begin___

If the firewall is enabled on Alcatel-Lucent OmniPCX Office Communication Server, onlypassive FTP is authorized. This parameter depends on the FTP too

Seite 32

Supported Windows OS Windows 2000 SP4 ProWindows 2000 ServerWindows XP Pro SP1+SP2Windows XP Home SP1+SP2Windows Server 2003, Server 2003 R2Unsupporte

Seite 33 - 2.4.1.16.2 Rack 2

Temporary substitutionThe replacement set keeps its own default functions (customized settings are not transferred).The data not transferred is stored

Seite 34 - 2.4.1.16.3 Rack 3

resource keys are not preserved. The directory numbers are preserved in accordance with thesize of the directories of the stations concerned (for exam

Seite 35

Figure 1.4: Second Generation cabinetNote:The Mini-MIX daughter board can be used only on a Compact Edition 2nd Generation with a CPU-3m ora CPU-4.%#

Seite 36

When adding sets, attention must be paid to the limits on the number of sets and the featuresoffered by the system software key.The set is recognized

Seite 37 -  

___change-end___Interface classification- UA link: TBTS- Hub/Alcatel Reflexes or Alcatel-Lucent 9 series 1 to 3 : TBTSMaximum distances between Alcate

Seite 38 - )# #" #

Figure 4.73: PATA Hard Disk Connection___change-begin______change-end___Figure 4.74: SATA Hard Disk ConnectionDuring installation, always take anti-st

Seite 39

It is possible to add one or two modules to the basic module.4.11.1.4.1 Fitting an add on module.- The CPU slot of the add on module must be fitted wi

Seite 40

RJ45 pin 1 2 3 4 5 6 7 8MAIN: TX+ TX- RX+ RX-- MAIN: HSL to basic module.4.11.1.4.3 Role of the # keyName Color FeaturePOWER Red/Green - Mains operati

Seite 41

5.1 Stations Default Configuration5.1.1 Detailed description5.1.1.1 DEFAULT CONFIGURATION5.1.1.1.1 Alcatel-Lucent 8 series and Alcatel-Lucent 9 series

Seite 42

Figure 5.1: Virtual Key Functions for Operator Sets in KeySystem modeChapter5(+5-2        

Seite 43

Figure 5.2: Virtual Key Functions for Manager/Assistant/Normal sets in KeySystem Mode(+        

Seite 44

Figure 5.3: Virtual Key Functions for Attendant sets in KeySystem Mode (with no PhysicalAdd-on)Chapter5(+5-4     

Seite 45 -   

Figure 5.4: Virtual and Physical Add-on Key Functions for Attendant Sets in KeySystem mode(+       

Seite 46

Chapter1%## $##1-6        

Seite 47 - 4.2 Connections and Cabling

Figure 5.5: [US only] Virtual Key Functions for Operator Sets in KeySystem ModeChapter5(+5-6       

Seite 48

Figure 5.6: [US only] Virtual Key Functions for Manager/Assistant Sets in KeySystem Mode(+       

Seite 49

Figure 5.7: [US only] Virtual Key Functions for Normal Sets in KeySystem ModeChapter5(+5-8       

Seite 50

Figure 5.8: Virtual Key Functions for Operator/Manager/Assistant/Normal Sets in PABX Mode(+       

Seite 51

Figure 5.9: [US only] Virtual Key Functions for Operator Sets in PABX ModeChapter5(+5-10        

Seite 52

Figure 5.10: [US only] Virtual Key Functions for Manager/Assistant Sets in PABX Mode(+        

Seite 53

Figure 5.11: [US only] Virtual Key Functions for Normal Sets in PABX ModeAlcatel-Lucent IP Touch 4028 Phone and Alcatel-Lucent 4029 Digital PhonesetsE

Seite 54

There are 10 pages of virtual keys (the pages can be scrolled through using the up/downbuttons of the set's 4-way navigator), with 4 virtual keys

Seite 55

Chapter5(+5-14        

Seite 56

6.1 System Startup from a Phone Set6.1.1 Configuration procedureYou can start-up the system using a phone set, provided this phone set is either anAlc

Seite 57

2.1 OverviewAlcatel-Lucent OmniPCX Office Communication Server is an "e-communication server", a new"all-in-one" concept combining

Seite 58

To restart the session from the beginning during programming.To restart the session if you quit using the Exit function6.1.1.2 SYSTEM TYPE: Used to de

Seite 59

: Used to choose one of the pre-programmed numbering plans: (2 to 4digits, national or with *).Any modification of the numbering plan causes the delet

Seite 60

orLook through the list of internal directory numbers andvalidate the entry displayed.Delete the digits contained in the field "Direct no."

Seite 61

10: Number of numbers still available in the DDI table after configuration of Direct Dialnumbers.In a Hotel installation, all the Z terminals are used

Seite 62

This function is only available for a business installation (in a Hotel only PCX mode isused)."PCX Mode" and "Intercom Mode"PCX Mo

Seite 63 - 4.3 Power Supply

This function is only available if your installation is fitted with DECT functionsThe ARI (Access Right Identifier) number identifies the system uniqu

Seite 64

Choice of language used on all the stations in the installation (displayand spoken help)6.1.1.12 BASIC METERING UNIT COSTThe value of the basic meteri

Seite 65

6.1.1.14 SYSTEM RESETThis menu is used to confirm resetting the system.System reset; the display shows "System reset in progress"After the r

Seite 66

- 1 Ethernet board (IP mode only; not required when there is a V24 serial port connection toAlcatel-Lucent OmniPCX Office Communication Server)- 64K (

Seite 67

- A connection to the switch connected to the main CPU board by a direct cable.The PC IP address and network mask must be compatible with the Alcatel-

Seite 68

- 56 ports.- 1 CPU slot 5 general-purpose slots.- Energy consumption: 1,2 A (230 V) / 2,3 A (110 V) - 120 W.- Dimension: H = 110 mm; W = 442 mm; D = 4

Seite 69

Remote access can be managed using:- an ISDN modem- an analog V34 modemRemote access using an ISDN modem.Alcatel-Lucent OmniPCX Office Communication S

Seite 70

1. Open OMC.2. Open the Tools folder.3. Open the OMC-Software Download application.4. In the Communication Mode window, select the type of download:•

Seite 71

• The Downloadable Item area allows you to see the different versions of theapplications constituting Alcatel-Lucent OmniPCX Office Communication Serv

Seite 72

Access to modes 2, 3, 4 and 5 is password protected: pbxk1064 (using the OMC tool)Access to modes 2 and 3 is password protected: help1954 (using the O

Seite 73

The 5 icons available in this mode (Terminals, Groups, System, Collective Directory andExternal Lines) are used to gain access to the wizards used to

Seite 74

- Metering• Cost of telephone metering• EasyPlus View: Hotel metering cost for current currency unit (VAT, prepaymentamount, etc.)• EasyPlus View: Met

Seite 75

This section will cover the following items in turn: types of Internet access, Internet services,Internet services administration systems, hardware an

Seite 76

Alcatel-Lucent OmniPCX Office Communication Server.- Access control: Alcatel-Lucent OmniPCX Office Communication Server offers controlsolutions for us

Seite 77

- verification of information prior to validation,- the possibility of choosing the display language (French, English, German, Italian, Spanish,Portug

Seite 78

navigation bar. The administration screens give access to the lists of:• Users per group• Connection profiles• Time Ranges• URL filter• Mailing lists•

Seite 79

- 14 ports.- 1 CPU slot + 1 MIX slot- Energy consumption: 1.5 A (240 V)- Dimension: H = 345 mm; W = 370 mm; D = 65 mm.- Weight: 5.1 kg.The following m

Seite 80

Page or the WBM Operator Home Page is displayed directly. It presents a summary ofthe system's activity.6.3.3.1.4 How to disconnectTo disconnect,

Seite 81

ISDN connection 1. Connection account:• User name: account delivered by the access provider. This is a uniqueaccount and authenticates the user when c

Seite 82

1. Click on the Connection Assistant icon. The Assistant connection window displays.2. In the Profile identification area, fill in the following field

Seite 83

and modify the desired parameters.6.3.5.1.3 CREATION OF A DSL MODEM/CABLE MODEM TYPE CONNECTIONClick on Wizards in the navigation bar. The assistants&

Seite 84

• IP address of the DSL modem: enter the IP address of the external modem.• Subnet mask: enter the defined mask.b. Click on Next. The Summary window d

Seite 85

Click on Wizards in the navigation bar. The assistants" icons appear.1. Click on the Connection Assistant icon. The "Connection Assistant&qu

Seite 86

- Testing the remote address by pinging the ISP's router. This checks that the router isworking properly.- DNS configuration check: this test is

Seite 87

7.1 Maintenance Level 17.1.1 MaintenanceThis module provides maintenance advice on different hardware components of theAlcatel-Lucent OmniPCX Office C

Seite 88 - 4.5 8 Series Sets

- sealed lead battery- 7 Ah / 12 V- fire resistance better than or equal to UL94-V27.1.1.2 BOARD BATTERY MAINTENANCEIt is recommended that the batteri

Seite 89

Always take anti-static precautions when handling boards. Before coming into direct physicalcontact with a board, make sure you touch a grounded metal

Seite 90

Figure 2.5: Mini-MIX connections on CPU-3m RJ45Equipment numbering:- Slot 80 EN 01 for the first T0 access (80-001-01)- Slot 80 EN 02 for the second T

Seite 91

1. If a hot installation is not possible, stop the system and disconnect it from the mains powersupply.2. Locate the required vacant slot in the cabin

Seite 92

malfunctioning of your installation.7.1.1.6.1 Handling- Always wear a discharge device (bracelet, heel clip, etc.) to protect against electrostaticdis

Seite 93

Chapter7# # #" #7-6        

Seite 94

8.1 Glossary8.1.1 AAutomatic Call DistributionA computerized phone system that responds to the caller with a voice menu, and connects the call to ther

Seite 95

Bandwidth Allocation Control Protocol. Control protocol associated with BAP.BAPBandwidth Allocation Protocol. PPP protocol that manages bandwidth by a

Seite 96

Direct Dialing In. Direct external call number for the system terminals (depending on the configuration withthe public network operator).DECTDigital E

Seite 97

8.1.8 HH.323ITU standard for multimedia communication (voice, video, data).H.450Additional services associated with H.323 version 2.HSLHigh Speed Link

Seite 98

ITUInternational Telecommunications Union : global coordination body.8.1.10 KKEY SYSTEM (mode)Reflexes terminal operating mode in which the terminal f

Seite 99 - 4.6 9 Series Sets

niPCX Office Communication Server systems.NMTNumbering Modification TableNNTPNetwork News Transfer Protocol. Protocol used by computers to handle mess

Seite 100 -   *+

PSTNPublic Switched Telephone Network.PTN(X)Private Telecommunications Network (eXchange). A private network consisting of switches and terminalsconne

Seite 101

2.3 Installation2.3.1 Overview2.3.1.1 INSTALLATION GUIDE&#' $(  #( #        

Seite 102

SIPSession Initiation Protocol. A signaling protocol for Internet conferencing, telephony, events notification, andinstant messaging. SIP initiates fo

Seite 103

URLUniform Resource Locator. Address of a resource (file, program, image, etc.) accessible on the Internet.UUSUser to User Signaling. Information carr

Seite 104 - 4.7 V24/CTI Interface Module

Chapter8%)8-10        

Seite 105

Legal notice:Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks ofAlcatel-Lucent. All other trademarks are the property of the

Seite 106

This hardware must be installed on the customer's site, by a qualified installer, incompliance with the instructions provided with the hardware.E

Seite 107

Board Function Optional boards ConnectionsCPU-3 Processing Unit (From R5.0) 128Mb Flash Memory.Optional Hard DriveHSL1, HSL2:interconnection withadd-o

Seite 108

Board Function Optional boards ConnectionsCoCPUCoCPU-1CoCPU-2CoProcessing Unit (Up to R1.1)CoProcessing Unit (From R2.0)CoProcessing Unit (From R3.1)V

Seite 109

Board Function Optional boards ConnectionsUAI4UAI8UAI16UAI16-14, 8 or 16 UA interfacesUAI16-1 board: possibility ofpowering terminals connected tothe

Seite 110 - 4.8 Intelligent Base Stations

Name Color FunctionCPU Green CPU functioning LED (flashing)POWER Red/Green - Mains operation: steady green LED- Battery operation: steady yellow LED-

Seite 111

WAN Green LED showing good WAN functioning (flashes when there is traffic);LED used if an ADSL modem is connected.2.4.1.3 CoProcessing Unit CoCPU-1 an

Seite 112

2.4.1.5 UAI-X BoardsBoard used for connecting up Alcatel Reflexes terminals or DECT 4070 IO/EO base stations.The UAI16-1 board is used to power termin

Seite 113

2.4.1.7 AMIX-1 X/Y/Z BoardsThese boards are used to connect 4 analog accesses, 4 or 8 analog terminals and 4 or 8Alcatel Reflexes dedicated terminals.

Seite 114

2.4.1.9.1 Function of the LEDsT2 Name T1 Name FunctionBUSY BUSY B-channels busy (red LED lights up if at least 1 B-channel is busy)RAI (ATD) RAI Remot

Seite 115

Each category-5 RJ45 connector has 2 green LEDs:- Left LED = link status and activity:• off: link disconnected• on: link connected• blinking: link act

Seite 116

Chapter 1General PresentationPreliminary ... 1.1Ov

Seite 117

2.4.1.13 DDI-X BoardThis board is used to connect 2 or 4 analog trunk lines with Multiple Subscriber Numbers.2.4.1.14 ATA BoardThe ATA (Analog Trunk A

Seite 118

DAUGHTERBOARDSCPU-1/CPU-2CPUe-1/CPUe-2CoCPU-1/CoCPU-2CPU-3 CPU-3m CPU-4SDRAM64 Yes No Yes Yes Yes NoSDRAM128 No No No No No YesSODIMM 256 No Yes No Ye

Seite 119

___change-end___Figure 2.26: Example of Daughter Boards on CPU-1___change-begin______change-end___Figure 2.27: Example of CPU with SATA Hard Disk2.4.1

Seite 120

Boards Slots 1-2 CPU SlotCPU-1, CPUe-1, CPU-2, CPUe-2, CPU-3,CPU-3m, CPU-4No ObligatoryMIX x/y/z Yes NoAMIX-1 x/y/z Yes NoUAI4, UAI8, UAI16, UAI16-1 Y

Seite 121 - 4.9 Client PCs

2.4.1.16.3 Rack 3Caution:The VoIP4-1, VoIP8-1 and VoIP16 boards implemented on a CPU board consume a hardware re-source used for slot 8 of the module.

Seite 122

Board MIX Slot CPU SlotCPU-2, CPU-3, CPU-3m, CPU-4 No ObligatoryMIX x/y/z Yes NoAMIX-1 x/y/z Yes NoMini-MIX No Yes&#' $(  #

Seite 123

Chapter2&#' $(  #( #2-22        

Seite 124

3.1 Software Licence Management3.1.1 SOFTWARE LICENCE MANAGEMENTOn an Alcatel-Lucent OmniPCX Office Communication Server several types of devices may

Seite 125

- the PRINC (PRINCIPAL) software key or MAIN for the system functions (voice, Internet,etc.)- the CTI Software key for the CTI functionsThe software k

Seite 126 - 4.10 PIMphony

3.2.1.1 Voice services available in "limited" mode- Stations in the default Attendant Group and analog sets with automatic call setup on goi

Seite 127

Chapter 3System ServicesSoftware Licence Management ... 3.1SOFTWARE LICENCE MANAGEMENT .

Seite 128

The following table lists the functions controlled by the "Main" software key, the "limited" modevalues and the configuration modu

Seite 129

Controlled services RelevantsoftwareversionValues inlimited modeModularity Max HardwareextensionLAN TELEPHONYNumber of IP Phones (e-Reflexes and IPTou

Seite 130

Controlled services RelevantsoftwareversionValues inlimited modeModularity Max HardwareextensionAccounting over IP From R5.0 closed open NOLANGUAGESNu

Seite 131

PIMphony Pro All 0 +1 250PIMphony Team All 0 +1 250Nomadic mode From R3 0 +1 25 (R4)50 (R5.0)PIMphony release 6.0 From R5.0 0 +1 50 (R4)60 (R5.0)PIMph

Seite 132

Number of sessions All 0 +1 1 *Number of monitors All 0 +1 250/500 **Features All None AllPIMphony UNIFIEDNumber of sessions From R3.1 0 +1 1 *Number

Seite 133

4.1 Presentation4.1.1 Overview4.1.1.1 LOCATION OF UNITThe Alcatel-Lucent OmniPCX Office Communication Server unit can be installed in threeways:1. Fix

Seite 134

4.1.1.1.2 Mounting in the 19" rackRecommendationsBefore installing the system in a 19" rack, you must verify that:- The maximum static load

Seite 135 - 

4.1.1.2 ENVIRONMENT4.1.1.2.1 Climatic conditions- Operation• Temperature: for maximum reliability, it is recommended you comply with an ambienttempera

Seite 136 - (+

All outputs are made using Female RJ45 connectors.Remark:the CPU-2 and MIX boards used for Alcatel-Lucent OmniPCX Office Compact Edition have the same

Seite 137

RJ45 pin 1 2 3 4 5 6 7 8LAN TX+ TX- RX+ RX-Up-Link TX+ TX- RX+ RX-Unit 1 to 3 outputs RX+ RX- TX+ TX-- LAN : 10/100 base T Ethernet port (MDI-II/strai

Seite 138

External connections ...4.64Intelligent Base Stations ...

Seite 139

- PBX: use in private network with TX and RX twisted pairs.4.2.1.1.8 LANX and LANX-1 boardRJ45 pin 1 2 3 4 5 6 7 8Ports 1 to 15 RX+ RX- TX+ TX-Up-Link

Seite 140

Access Type ImpedanceAlcatel Reflexes, Z, T0,LRUTP, FTP or STP, Category 3 or 5 100 or 120 ohmsT2 UTP, FTP or STP, Category 3 or 5 120 OhmsT1 UTP, FTP

Seite 141

4.2.1.4 CONNECTING TERMINALS4.2.1.4.1 Connection of Alcatel Reflexes terminalsThe terminals are equipped with a cable and a self-acting switch that pl

Seite 142

System - Reflexes terminal distances:- 0.5 mm SYT type cable: 800 m (station without option) or 600 m (station with S0 or Zoption).- 278 type 0.6 mm c

Seite 143

4.2.1.4.2 Connecting analog terminalsThe terminals are equipped with a cable and a self-acting switch that plugs into the wallsocket. Each terminal is

Seite 144

Caution:The AFU-1 board (daughter board of the CPU board) must obligatorily be fitted to detect the ab-sence of power.The ISDN-EFM box must be install

Seite 145

4.2.1.5.2 Digital Public Network by T1 or T2 accessThe diagram below shows a PRA-T2 board, but is equally applicable for a PRA-T1 board.Chapter4

Seite 146

The PRA board is connected to a digital line termination (DLT) by 2 symmetrical twisted pairs.Cable impedance: 120 Ohms +/- 20% between 200kHz and 1MH

Seite 147

4.2.1.5.4 Analog Public Network - Direct Dialing In.4.2.1.6 LAN CONNECTIONThe LANX8/LANX16 board is used to connect servers, PCs, IP terminals and ext

Seite 148

Category 5 cable, FTP or STP, impedance 100 Ohms: maximum length 100 m.4.2.1.7 CONNECTING AUXILIARY EQUIPMENTAll auxiliary equipment is connected via

Seite 149 - 

Services provided ...6.18WBM Managing Tool ...

Seite 150 - 

Audio input characteristics:Input impedance : 600 OhmsFuse characteristics:- Max. power : 10 W- Max. voltage : 60 V- Max. current : 500 mAThe contacts

Seite 151

4.2.1.7.3 Connecting an alarmThe alarm is activated in the event of a false stopping of the system.It is connected via the ALARM output (control conta

Seite 152

4.2.1.7.6 Connecting a doorphone2 doorphone types are available, depending on the operating mode used:- Type A: relay-controlled doorphones (e.g. NPTT

Seite 153

- A single doorphone with doorstrike may be connected to the system.- The system also allows for the connection of 2 doorphones without latch.Connecti

Seite 154

socket-outlet is installed near the equipment and is easily accessible.4.3.1.2 BATTERY IMPLEMENTATIONAlcatel-Lucent OmniPCX Office Communication Serve

Seite 155

External battery units are available in different versions. The required version depends on yourAlcatel-Lucent OmniPCX Office Communication Server uni

Seite 156

- Batteries must be charged prior to installation.Figure 4.24: Wiring diagram of a 12V external battery rack unit (2 or 3x7Ah in parallel)Figure 4.25:

Seite 157 - 6.2 System Startup from OMC

3. Place the batteries flat in the unit and close it.4. Turn off the switch, and check the battery voltage directly on the connector at the rear ofthe

Seite 158

4. Connect the negative (black) terminals of the batteries as described below (and shown inthe figure below).a. Connect the middle connector of the bl

Seite 159

6. Close the unit and secure it with the four screws.7. Stick a label on the unit stating the date of the installation and the number of batteriesinst

Seite 160

Q ... 8.7R ...

Seite 161

4. Connect the terminals of the batteries strictly in the order detailed below (also see thefigure below).a. Connect the black wire to the negative (b

Seite 162

c. Connect the two units using the extension cable between the J2 connectors on theunits; the cable's Mate-N-Lok 3-terminal connector must be con

Seite 163

4. Remove the fan connector, then remove the power supply unit and the battery unit.5. Replace the battery cable with the new cable provided with the

Seite 164

7. Remove the mounting clip and the batteries from the internal battery support.8. Put the empty battery support and the power supply unit back in pla

Seite 165

4. If the BAT IN/EXT connector is present, remove the red jumper.5. Remove the cover from the hole provided for the connecting cable on the rear panel

Seite 166

You must first prepare the external battery unit for use and then connect this unit to theAlcatel-Lucent OmniPCX Office Compact Edition unit. These tw

Seite 167

3. Connect the negative (black) terminals of the batteries as described below (and shown inthe figure below).a. Connect the middle connector of the bl

Seite 168

5. Close the unit and secure it with the four screws.6. Stick a label on the unit stating the date of the installation and the number of batteriesinst

Seite 169

3. Push the power supply module back into the cabinet and secure it in place with ascrewdriver.4. Now on the external battery unit:a. Ensure that the

Seite 170

4.3.1.5.1 Alcatel-Lucent OmniPCX Office Communication Server (S, M or L rack)The connection can be made using electrical installations of the followin

Seite 171

     ! " # ! $# 0-6        

Seite 172

For performance and safety reasons, the system must always be connected to theground. The ground must be connected prior to all the other connections.

Seite 173

Attaching the line cable:- Turn the terminal- Remove the panel at the rear of the terminal (pull it towards the interior of the terminal andthen pull

Seite 174

- Attach the terminal using the two lugs: introduce the lugs into the holes previouslyoccupied by the feet (left foot and hole intended for this purpo

Seite 175

List of abbreviations- TD: Transmit data - RD: Receive data- RTS: flow control output - CTS: flow control outputAdding a Sector- Turn the set and the

Seite 176

- Plug in the handset cable (connector ) into the guide intended for this purpose.Wall mountedPreparing the terminal- Turn the terminal- Unscrew A and

Seite 177 - ! 

For Alcatel-Lucent First and Easy Reflexes terminals, the optional module is external to theterminal; this module can be placed on a table or wall mou

Seite 178 - # # #" #

The e-Reflexes terminals are connected to:1. A PC (optional). The PC is a workstation that uses the station's switch function (linkthrough straig

Seite 179

- Manual, if the terminals are not connected to a same subnet as Alcatel-Lucent OmniPCXOffice Communication Server, or if the DHCP server integrated i

Seite 180

For more information, refer to the section Voice over IP in the product documentation.4.5 8 Series Sets4.5.1 IPTouch 4008/4018 Phone4.5.1.1 Commission

Seite 181

- Initialize the set- Program keysPrerequisitesNone.Connecting the setsThis section describes how to:- Connect an IP Touch set to the LAN (Local Area

Seite 182

1.1 Preliminary1.1.1 Overview1.1.1.1 SYMBOLS USED IN THE DOCUMENTATIONSee note.See important information.1.1.1.2 CLAUSESCopyright and TrademarksDatali

Seite 183 - 

Choosing the initialization modeThe default mode is dynamic mode.To choose the initialization mode, refer to the table below.table 4.21: Initializatio

Seite 184 - %)

Static 1. Connect the power supply.2. Before initialization phase 5 starts, press i, then the # key.The Main menu appears.3. From the Main menu, choos

Seite 185

In the procedure below, it is assumed that:- there is one DHCP server- no VLAN has to be configured.PrerequisitesNone.Relocating and retaining the sam

Seite 186

Figure 4.50: Alcatel-Lucent IP Touch 4028 Phone, Alcatel-Lucent IP Touch 4038 Phone andAlcatel-Lucent IP Touch 4068 Phone connectors4.5.2.1.2 Commissi

Seite 187

To connect the set to the LAN:1. Turn the set over so that you can see its base.2. Plug the RJ45 cable into the set's LAN connector.3. Connect th

Seite 188

You do not have a DHCPserverStatic mode - Refer to table: Initializationprocedure- Obtain from your networkadministrator:• An IP address for theIP Tou

Seite 189

Static 1. Connect the power supply.2. Before initialization phase 5 starts, press i, then the # key.The Main menu appears.3. From the Main menu, choos

Seite 190

- AOM Alcatel-Lucent 8 series and Alcatel-Lucent 9 series Smart Display Module provides14 keys with programmable LCD labelsPrerequisitesNone.Rules and

Seite 191

The 3.5 mm female jack can receive an external station speaker jack.In order to take the external station speaker into account, the set customization

Seite 192

2. Select Name and enter the name to be associated with the selected key, then press OK.The desired name is associated with the key.3. Select Number a