Combo Port Application Example Configuring Ethernet Ports
page 1-24 OmniSwitch 6800/6850/9000 Network Configuration Guide June 2006
Combo Port Application Example
The figure below shows a sample application example for using OmniSwitch 6800 Series combo ports.
Workstations A and B are connected with 100 Mbps links to copper combo ports 1/45 and 1/46, respec-
tively. (MiniGBIC SFP combo ports 1/45 and 1/46 are unused.) Server A has a primary 1 Gbps fiber
connection to combo MiniGBIC SFP port 1/47 and a backup 100 Mbps connection to copper combo port
1/47. And the OmniSwitch 9700 has a primary 1 Gbps connection to combo MiniGBIC SFP port 1/48 and
a backup 100 MBps connection to copper combo port 1/48.
Combo Port Application Example
Follow the steps below to configure this application example:
1 Set the speed of copper combo ports 1/45 through 1/48 to 100 Mbps with the interfaces hybrid speed
command by entering:
-> interfaces 1/45-48 hybrid copper speed 100
2 Set copper combo ports 1/45 and 1/46 to forced copper mode—which will ensure the links stay up even
if a cable is plugged into MiniGBIC SFP combo ports 1/45/ and 1/46—with the interfaces hybrid forced-
copper command by entering:
-> interfaces 1/45-46 hybrid forced-copper
OmniSwitch 9700
TM
OmniSwitch 6800 Series Switch
Workstation A connected
to RJ-45 port 1/45.
Server A connected to
MiniGBIC SFP port 1/47
(primary) and RJ-45 port
1/47 (backup).
Workstation B connected
to RJ-45 port 1/46.
OmniSwitch 9700 A con-
nected to MiniGBIC SFP
port 1/48 (primary) and
RJ-45 port 1/48 (backup).
100 Mbps
1 Gbps
Kommentare zu diesen Handbüchern