Monitoring Switch Health Diagnosing Switch Problems
page 29-40 OmniSwitch 6800/6850/9000 Network Configuration Guide June 2006
For example, to specify a CPU usage threshold of 85 percent, enter the following command:
-> health threshold cpu 85
For more information on the health threshold command, refer to Chapter 36, “Health Monitoring
Commands,” in the OmniSwitch CLI Reference Guide.
Note. When you specify a new value for a threshold limit, the value is automatically applied across all
levels of the switch (switch, module, and port). You cannot select differing values for each level.
Displaying Health Threshold Limits
The show health threshold command is used to view all current health thresholds on the switch, as well
as individual thresholds for input traffic (RX), output/input traffic (TX/RX), memory usage, CPU usage,
and chassis temperature.
To view all health thresholds, enter the following command:
-> show health threshold
Rx Threshold = 80
TxRx Threshold = 80
Memory Threshold = 80
CPU Threshold = 80
Temperature Threshold = 60
To display a specific health threshold, enter the show health threshold command, followed by the appro-
priate suffix syntax:
rx
txrx
memory
cpu
temperature
For example, if you want to view only the health threshold for memory usage, enter the following
command:
-> show health threshold memory
Memory Threshold = 80
memory Specifies a value for the memory usage threshold. Memory usage
refers to the total amount of RAM memory currently used by switch
applications. The default memory usage threshold is 80 percent.
cpu Specifies a value for the CPU usage threshold. CPU usage refers to the
total amount of CPU processor capacity currently used by switch appli-
cations. The default CPU usage threshold is 80 percent.
temperature Specifies a value for the chassis temperature threshold (Celsius).
The default temperature threshold is 60 degrees Celsius.